Fume / Odor Control

In this application there were high concentrations of fume / blended spices odor coming out of the Donaldson dust collector, we installed a carbon and chemical dry media scrubber with filter media supplied by Aphasorb Technologies, this high resistance system required its own exhaust fan which discharged the clean air through a twelve meter stack, the two fans were balanced with the use of electrical frequency inverters allowing the systems to work in tandem